nut
Affected
- introduced
0(ecosystem)
Fixed versions
None listed
Fix
No fixed version is listed.
Advisory
Also known as: CVE-2026-85068
The record has no summary.
Network UPS Tools is a collection of programs which provide a common interface for monitoring and administering UPS, PDU and SCD hardware. From 2.4.2 through 2.8.5, ippon_command in drivers/blazer_usb.c partially initializes char tmp[64] with a short Megatec status query and then passes a fixed eight-byte chunk to usb_control_msg. A malicious firmware-controlled USB device presenting the Mustek Powermust VID 0x06da and Mustek Powermust PID 0x0003 matches blazer_usb_id, selects ippon_subdriver, and can receive the uninitialized trailing stack bytes during normal polling. The disclosure is bounded and read-only, requires physical or supply-chain access to the USB bus, and has no established integrity or availability impact. This issue is scheduled to be fixed in version 2.8.6.
Low Basis: CVSS v3 score 2.4, vector CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
0 (ecosystem)None listed
No fixed version is listed.
0 (ecosystem)None listed
No fixed version is listed.
Fix commands are the export's own generic commands. Ojuju never runs them. Check them against your setup first.
Check your own computer: guard packages check
Source: Debian Security Tracker (converted by OSV.dev)
Debian Security Tracker, converted to OSV by OSV.dev.