Advisory

GHSA-qqfj-4vcm-26hv

Also known as: CVE-2026-34944, RUSTSEC-2026-0087

Summary

Wasmtime segfault or unused out-of-sandbox load with f64x2.splat operator on x86-64

Details

On x86-64 platforms with SSE3 disabled Wasmtime's compilation of the f64x2.splat WebAssembly instruction with Cranelift may load 8 more bytes than is necessary. When signals-based-traps are disabled this can result in a uncaught segfault due to loading from unmapped guard pages. With guard pages disabled it's possible for out-of-sandbox data to be loaded, but this data is not visible to WebAssembly guests.

Details

The f64x2.splat operator, when operating on a value loaded from a memory (for example with f64.load), compiles with Cranelift to code on x86-64 without SSE3 that loads 128 bits (16 bytes) rather than the expected 64 bits (8 bytes) from memory. When the address is in-bounds for a (correct) 8-byte load but not an (incorrect) 16-byte load, this can load beyond memory by up to 8 bytes. This can result in three different behaviors depending on Wasmtime's configuration:

  1. If guard pages are disabled then this extra data will be loaded. The extra data is present in the upper bits of a register, but the upper bits are not visible to WebAssembly guests. Actually witnessing this data would require a different bug in Cranelift, of which none are known. Thus in this situation while it's something we're patching in Cranelift it's not a security issue.
  2. If guard pages are enabled, and signals-based-traps are enabled, then this operation will result in a safe WebAssembly trap. The trap is incorrect because the load is not out-of-bounds as defined by WebAssembly, but this mistakenly widened load will load bytes from an unmapped guard page, causing a segfault which is caught and handled as a Wasm trap. In this situation this is not a security issue, but we're patching Cranelift to fix the WebAssembly behavior.
  3. If guard pages are enabled, and signals-based-traps are disabled, then this operation results in an uncaught segfault. Like the previous case with guard pages enabled this will load from an unmapped guard page. Unlike before, however, signals-based-traps are disabled meaning that signal handlers aren't configured. The resulting segfault will, by default, terminate the process. This is a security issue from a DoS perspective, but does not represent an arbitrary read or write from WebAssembly, for example.

Wasmtime's default configuration is case (2) in this case. That means that Wasmtime, by default, incorrectly executes this
WebAssembly instruction but does not have insecure behavior.

Impact

If signals-based-traps are disabled and guard pages are enabled then guests can trigger an uncaught segfault in the host, likely aborting the host process. This represents, for example, a DoS vector for WebAssembly guests.

This bug does not affect Wasmtime's default configuration and requires signals-based-traps to be disabled. This bug only affects the x86-64 target with the SSE3 feature disabled and the Cranelift backend (Wasmtime's default backend).

Patches

Wasmtime 24.0.7, 36.0.7, 42.0.2, and 43.0.1 have been issued to fix this bug. Users are recommended to update to these patched versions of Wasmtime.

Workarounds

This bug only affects x86-64 hosts where SSE3 is disabled. If SSE3 is enabled or if a non-x86-64 host is used then hosts are not affect. Otherwise there are no known workarounds to this issue.

Severity

Medium Basis: The source's own band: MODERATE

Dates

Published
2026-04-09 20:22 UTC
Modified
2026-09-10 03:51 UTC

Affected packages and fixes

wasmtime

crates.io · All systems

Affected

  • introduced 0, fixed 24.0.7 (semver)

Fixed versions

24.0.7

Fix

  • Fixed version 24.0.7
    cargo update -p wasmtime --precise 24.0.7

wasmtime

crates.io · All systems

Affected

  • introduced 25.0.0, fixed 36.0.7 (semver)

Fixed versions

36.0.7

Fix

  • Fixed version 36.0.7
    cargo update -p wasmtime --precise 36.0.7

wasmtime

crates.io · All systems

Affected

  • introduced 37.0.0, fixed 42.0.2 (semver)

Fixed versions

42.0.2

Fix

  • Fixed version 42.0.2
    cargo update -p wasmtime --precise 42.0.2

wasmtime

crates.io · All systems

Affected

  • introduced 43.0.0, fixed 43.0.1 (semver)

Fixed versions

43.0.1

Fix

  • Fixed version 43.0.1
    cargo update -p wasmtime --precise 43.0.1

Fix commands are the export's own generic commands. Ojuju never runs them. Check them against your setup first.

Check your own computer: guard packages check

View this record on OSV.dev

Source

Source: GitHub Advisory Database (reviewed advisories) · CC BY 4.0

Sources & licences