systemds
Affected
- introduced
0, fixed2.2.2(ecosystem)
Fixed versions
2.2.2
Fix
- Fixed version
2.2.2pip install --upgrade systemds==2.2.2
Advisory
Also known as: CVE-2022-26477, GHSA-m43h-hfrq-x8wx
The record has no summary.
The Security Team noticed that the termination condition of the for loop in the readExternal method is a controllable variable, which, if tampered with, may lead to CPU exhaustion. As a fix, we added an upper bound and termination condition in the read and write logic. We classify it as a "low-priority but useful improvement". SystemDS is a distributed system and needs to serialize/deserialize data but in many code paths (e.g., on Spark broadcast/shuffle or writing to sequence files) the byte stream is anyway protected by additional CRC fingerprints. In this particular case though, the number of decoders is upper-bounded by twice the number of columns, which means an attacker would need to modify two entries in the byte stream in a consistent manner. By adding these checks robustness was strictly improved with almost zero overhead. These code changes are available in versions higher than 2.2.1.
Not rated by the source.
0, fixed 2.2.2 (ecosystem)2.2.2
2.2.2pip install --upgrade systemds==2.2.2Fix commands are the export's own generic commands. Ojuju never runs them. Check them against your setup first.
Check your own computer: guard packages check
Source: PyPA Advisory Database · CC BY 4.0