Advisory

PYSEC-2026-954

Also known as: BIT-tensorflow-2023-27579, CVE-2023-27579, GHSA-5w96-866f-6rm8, PYSEC-2026-3111, PYSEC-2026-3279

Summary

TensorFlow has Floating Point Exception in TFLite in conv kernel

Details

Impact
Constructing a tflite model with a paramater filter_input_channel of less than 1 gives a FPE.

Patches
We have patched the issue in GitHub commit 34f8368c535253f5c9cb3a303297743b62442aaa.

The fix will be included in TensorFlow 2.12. We will also cherrypick this commit on TensorFlow 2.11.1.

For more information
Please consult our security guide for more information regarding the security model and how to contact us with issues and questions.

Attribution
This vulnerability was reported by Wang Xuan of Qihoo 360 AIVul Team.

Severity

High Basis: CVSS v3 score 7.5, vector CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H

Dates

Published
2026-07-07 10:17 UTC
Modified
2026-07-13 16:42 UTC

Affected packages and fixes

tensorflow-gpu

PyPI · All systems

Affected

  • introduced 0, fixed 2.11.1 (ecosystem)

Fixed versions

2.11.1

Fix

  • Fixed version 2.11.1
    pip install --upgrade tensorflow-gpu==2.11.1

Fix commands are the export's own generic commands. Ojuju never runs them. Check them against your setup first.

Check your own computer: guard packages check

View this record on OSV.dev

Source

Source: PyPA Advisory Database · CC BY 4.0

Sources & licences